3M00

Mixing 2 (evo)

Combined Thereapy

Mixing2 is an electrotherapy stimulator with an integrated ultrasound unit. It has two independent stimulation channels with adjustable intensity for delivering low and medium frequency treatments. The ultrasound unit operates at a frequency of 1MHz. Ultrasound operation is either independent or in combination with one of the two stimulator channels.

The Patient Data Bank allows the storage of

  • patient data
  • pathologies
  • treatment description
  • customisation of treatment
  • assessment of pain level at the beginning and end of treatment

Our patient database provides immediate access to customised treatment, allowing it to be repeated easily and quickly.

Programmes and Sequences: large memory to store new programmes and sequences of combined programmes. This makes it possible to create customised treatments tailored to the patient's specific needs.

Phone orders
+390516836385
Customer service
+390516836385
Mixing 2 (evo)

Combined Thereapy

  • Features
  • Continuous output with max. power of 2W/cm2
  • Pulse output with max. power of 3W/cm2
  • Pre-set programmes for common pathologies
  • Visual and acoustic no-contact signal
  • Real treatment time (time stops in case of no-contact)
  • Large graphic display showing all output parameters
  • Ultrasound unit connection function with stimulation channel for combination therapy
  • 11 stimulation modes (current types)
  • Preset protocols for simple or combined treatment
  • User-programmable protocols for each of the 11 output modes
  • Possibility of sequencing programmes belonging to the same output mode
  • Constant current / constant voltage
  • Intuitive system
  • Patient database
  • Possibility to store modified programmes and protocol sequences
  • included aaccessories

1 pc. - 1MHz/5cm2 head ultras. (A01.00053)
1 pc. - Gel tube 260gr. (R/273)
2 pcs. - Electrostimulation cables (C/IS)
4 pcs. - Electrodes 60X40 mm (EL/1)
2 pcs. - Electrodes 60X60 mm (EL/2)
2 pcs. - Electrodes 60X120 mm (EL/3)
4 pcs. - Sponge for EL/1 (A02.00316)
2 pcs. - Sponge for EL/2 (A02.00317)
2 pcs. - Sponge for EL/3 (A02.00318)
2 pcs. - Elastic band 50 cm (F6)
2 pcs. - Elastic band 100 cm (F7)
1 pc. - Split cable black (C/DU-N)
1 pc. - Split cable red (C/DU-R)
1 pc. - Cable black plug 2mm (C/RD-N)
1 pc. - Cable red plug 2mm (C/RD-R)

  • Technical data chart

Power supply: 230 V (±10%) 50 Hz
Power consumption: 80 VA
Weight: 4.2 kg
Dimensions (LxWxH): 33 x 32.8 x 23 cm
Insulation Class: Class I - Type BF


Ultrasonic Technical Data
Rated frequency: 1MHz
Number of heads: 1
Pulse frequency: 100Hz
Output: continuous and pulsed
Intensity: 0 ÷ 2W/cm2 continuous
0 ÷ 3W/cm2 pulsed
Ultrasound head: 1MHz, 5 cm2with no-contact light indication, suitable for underwater treatments
Time: 0 ÷ 30 min

  • Stimulation mode
  • Tens: Presenta molti programmi residenti per le patologie più comuni. Frequenza: 2 ÷ 200 Hz. Durata dell’impulso: 50 ÷ 600 μs. Intensità: 0 ÷ 250 mA (Ipp).
  • NMES: impulsi bidirezionali simmetrici. Dispone di un file con una serie di prog. per il trattamento di diverse condizioni muscolari. Freq.: 2 ÷ 200Hz. Durata: 50 ÷ 600 μs. Intensità: 0 ÷ 250mA (Ipp).
  • Interferenziale: corrente interferenziale a due poli modulata in ampiezza (AMF). Frequenza delle onde quadrate: 4000Hz. (± 20%) Frequenza sinusoidale di modulazione: 5 ÷ 200Hz. Intensità: 0 ÷ 250mA (Ipp).
  • Vettore interferenziale tetrapolare: corrente interferenziale modulata inampiezza (AMF). Frequenza d’onda quadrata 4000Hz. Frequenza sinusoidale di modulazione 5 ÷ 200Hz, intensità 0 ÷ 250 mA (Ipp)
  • Kotz: corrente sinusoidale interrotta. Frequenza sinusoidale: 1000 ÷ 2500Hz. Frequenza di modulazione: 5 ÷ 200Hz. Intensità: 0 ÷ 250mA (Ipp).
  • Corrente Faradica: impulsi esponenziali monodirezionali. Frequenza: 1 ÷ 100Hz. Intensità: 0 ÷ 130mA (Ip).
  • Ionoforesi: corrente monodirezionale a media frequenza. Frequenza: 8000 Hz. Duty Cycle: 95%.
  • Intensità: 0 ÷ 30mA (Ip).
  • Corrente Diadinamica: correnti sinusoidali monodirezionali monofase (MF), bifase (DF), breve periodo (CP), lungo periodo (LP). Intensità: 0 ÷ 30mA (Ip).
  • Impulsi: impulsi unidirezionali rettangolari e triangolari. Durata: 1 ÷ 1000 ms. Pausa: 1 ÷ 5 s. Intensità: 0 ÷ 30 mA
  • Traebert: corrente monodirezionale rettangolare. Durata dell’impulso: 2 ms. Pausa: 5 ms. Intensità: 0 ÷ 30 mA (Ip)
  • Urologia: impulsi bidirezionali simmetrici. Frequenza: 2 ÷ 200 Hz. Durata dell’impulso: 50 ÷ 600 μs. Corrente massima: 250 mA (Ipp). Caratteristica di uscita: tensione costante (CV)
Optional accessories
Point handpiece
Vaginal electrode Ø25 x 14 mm
Vaginal electrode Ø25 x 10 mm
Vaginal electrode Ø25 x 10 mm
Trolley Model 'Z