Tens: Features many resident programmes for the most common pathologies. Frequency: 2 ÷ 200 Hz. Pulse duration: 50 ÷ 600 μs. Intensity: 0 ÷ 250 mA (Ipp).
NMES: Symmetrical bidirectional pulses. It has a file with a series of programmes for treating different muscular conditions. Frequency: 2 ÷ 200 Hz. Duration: 50 ÷ 600 μs. Intensity: 0 ÷ 250 mA (Ipp).
Bipolar interferential current: amplitude-modulated two-pole interferential current (AMF). Square wave frequency: 2000 ÷ 4000 Hz. (± 20%). Sinusoidal modulation frequency: 5 ÷ 200 Hz. Intensity: 0 ÷ 200 mA (Ipp).
Tetrapolar interference vector: amplitude modulated bidirectional current (AMF). Sinusoidal frequency 2000 ÷ 10,000 Hz. Sinusoidal modulation frequency 5 ÷ 200 Hz. Intensity 0 ÷ 125 mA (Ipp).
Burst: bidirectional symmetrical rectangular pulses. Action: 0.25 s. Pause: 0.75 s. Frequency: 2 ÷ 200 Hz. Pulse duration: 50 ÷ 600 μs.
Kotz: sinusoidal interrupted current. Sinusoidal frequency: 1000 ÷ 2500 Hz. Modulation frequency: 5 ÷ 200 Hz. Intensity: 0 ÷ 250 mA (Ipp).
Trabert: rectangular one-way current. Pulse duration: 2 ms. Pause: 5 ms. Intensity: 0 ÷ 45 mA (Ip).
AMF: bidirectional symmetrical rectangular pulses. Increase: 2 s. Decrease: 1 s. Rest: 2 s. Frequency: 2 ÷ 200 Hz. Pulse duration: 50 ÷ 600 μs.
Faradic current: one-way exponential pulses. Frequency: 1 ÷ 100 Hz. Intensity: 0 ÷ 150 mA (Ip).
Iontophoresis: one-way medium-frequency current. Frequency: 8000 Hz. Duty Cycle: 95%.Intensity: 0 ÷ 50 mA (Ip).
FM: rectangular bidirectional symmetrical pulses. Adjustable pulses from 2 ÷ 10 Hz. Adjustable pulse duration. Frequency: 2 ÷ 200 Hz. Pulse duration: 50 ÷ 600 μs.
Diadynamic currents: one-phase (mf) and two-phase (DF), short period (CP), long period (LP) sinusoidal currents. Intensity: 0 ÷ 50mA (Ip).
Triangular/exponential pulses: triangular monodirectional pulses. Duration: 1 ÷ 1000 ms. Pause: 1 ÷ 10 s. Intensity: 0 ÷ 50 mA (Ip).
Rectangular pulses: monodirectional rectangular pulses. Duration: 1 ÷ 1000 ms. Pause: 1 ÷ 10 s. Intensity: 0 ÷ 50 mA (Ip).
Agonist/Antagonist: symmetrical bidirectional rectangular pulses. Stimulation of agonist/antagonist muscles.
Agonist/Antagonist with Faradic current: monodirectional pulses. Frequency: 1÷100 Hz. Intensity: 0÷150 mA (Ip).
Agonist/Antagonist with Kotz current: Interrupted sinusoidal current. Sinusoidal frequency: 1000 ÷ 2500 Hz. Modulation frequency: 5 ÷ 200 Hz. Intensity: 0 ÷ 250 mA (Ipp).
Diagnostics: intensity/time curve detection. Automatic calculation of rheobase, chronaxis, accommodation and curve drawing. Possibility of storing the results and recording them on the database.