EVO.1064

High-power laser therapy

High-power laser therapy

EVOLASER 1064 enables a variety of therapeutic applications, making it the most versatile laser device on the market:

  • High power output;
  • Continuous and pulsed modes up to 10,000Hz;
  • Duty cycle between 20% and 80%;
  • Possibility of creating complex programmes by combining spot and scanning method;
  • Frequency and Duty Cycle adjustment;
  • Use of beam expander for treatment of large areas;
  • BURST emission mode;
  • Test of actual power output.

The EVOLASER 1064 incorporates a computer that offers almost infinite programming capabilities and allows the operator to enter patient data, including information on the history and evolution of their disease.
The use of state-of-the-art US-made laser modules together with a very high-efficiency optical fibre (ultra-low attenuation) and suitable for carrying several hundred watts, guarantees the emission of a high-quality ultra-pure laser beam. Thanks to this excellent quality, the laser beam can penetrate to a depth of more than 10 cm.

 

Phone orders
+390516836385
Customer service
+390516836385
High-power laser therapy

High-power laser therapy

  • Features
  • The USB connection allows patient data to be transferred to an external database and the software to be updated.
  • With its T.E.C. (Total Emission Control) system, the EVOLASER 1064 offers unrivalled parameter flexibility and enables the delivery of ultra-high power density without overheating tissue. It also features an automatic system for controlling the amount of energy delivered.
  • M.P.P. System (Multi Parameters Protocols): complex programmes and protocols that change frequency, duty cycle, pulse duration, sweep, rest/action frequency, intensity and relaxation time. they are changed automatically during the programme without operator intervention.
  • The power output of the laser handpiece can be verified via the integrated readout system on the device. It is also possible to check the efficiency and integrity of the optical fibre.
  • included aaccessories

1 pc. - Operator protective goggles (OPO)
1 pc. - Foot switch (D02.00605)
1 pc. - Patient protective goggles (OPP)

  • Technical data chart

Laser source: GaAlAs laser diode

Wavelength: 1064 nm

Guiding light: 635 nm laser (±3%), < 3mW

Operation: Continuous (CW), pulsed, hyper-pulsed, M.P.P. (Multi Parameter Protocol), T.E.C. (Total Emission Control), S.P.S. (Point Scanner)

Output fibre power: 13 W (CW)

Target Indicator: 3 mW red laser pointer

IR spot size: 1.70 cm2 at 1 cm distance from patient's skin

beam expansion area of 30 cm2

Time: Digital display of actual treatment time

Power supply: 230 V~ 50 Hz

Input: 145 VA

Weight: 4.7 kg

Dimensions: 27 x 44 x 23 cm

Class: 4

Insulation Class: Class I - Type BF

Optional accessories
Trolley Model 'Z
30 cm2 cone
Cone support arm